Main Switch Board (I-Type)

Main Switch Board (I-Type)

Brand: King Power

5/5

Comply with IEC 61439-1&2 standard
Dielectric propeties characteristic: Rated insulation voltage Ui
Rated operations voltage Ue: 415V
Rated impulse withstand voltage Uimp: 8kV
Overvoltage category: IV
Pollution degree: 3
Main busbar characteristic: Rated current In

Follow us:

Description

System Overview

MOUNTING DESIGN 1,2 CIRCUIT BREAKER DESIGN 3,4,5 CIRCUIT BREAKER DESIGN 6,7,8,9 CIRCUIT BREAKER DESIGN
Comply with IEC standard Comply with IEC-61439-1&2 IEC 60529 standard Comply with IEC-61439-1&2 IEC 60529 standard Comply with IEC-61439-1&2 IEC 60529 standard
Functions + Outgoing feeder

+ Central reactive power compensation

+ Busway feeders

+ Supply

+ Surge arrester

+ Connections busbar

+ Cable feeders

+ Coupling

+ Supply

+ Connections busbar

+ Outgoing feeder

Rated values Up to 6300A Up to 6300A Up to 6300A
Connection position Front or rear Front or rear Front or rear
Cubicle width (mm) 550,600,650,700,750…1500mm 300,550,600,650,700…1500mm 550,600,650,700…1500mm
Internal separation Form 1, 2a, 2b, 3a, 3b, 4a, 4b Form 1, 2a, 2b, 3a, 3b, 4a, 4b Form 1, 2a, 2b, 3a, 3b, 4a, 4b
Busbar position Between Between Between
Thickness of Materia + Thickness of Frame 2mm

+ Thickness of outer door 2mm

+ Thickness of inner door 2mm

+ Thickness of back cover 2mm

+ Thickness of side plate 2mm

+ Thickness of Frame 2mm

+ Thickness of outer door 2mm

+ Thickness of inner door 2mm

+ Thickness of back cover 2mm

+ Thickness of side plate 2mm

+ Thickness of Frame 2mm

+ Thickness of outer door 2mm

+ Thickness of inner door 2mm

+ Thickness of back cover 2mm

+ Thickness of side plate 2mm

 

 

Simple integration of low-voltage power distribution components

MOUNTING DESIGN 1,2 CIRCUIT BREAKER DESIGN 3,4 CIRCUIT BREAKER DESIGN 5,6,7,8 CIRCUIT BREAKER DESIGN
Functions + Compensation

+ Outgoing feeder

+ Comprehensive protection of
people and plants against damage through fire, electric
shock, lightning, or overvoltage+ High level of personal and
plant safety
+ Reliably protect people and plants

+ System has three mode
Auto-Off-Man

+ When electrical power from
transformer have problem, ATS will auto transfer to generator, when electrical power from transformer is ok, ATS will auto transfer electrical
power from generator to tranformer

+ Outgoing feeder supply to
distributions panel

Special features Including ACB, MCCB, Contactor and capacity, Power Factor Regulator

Including ACB and ampe
meter, volt meter, protection
equipment as is Surge Arrestor,
over-under voltage relay (O/UV)
over current earth fault relay
(OC/EF)

 

Including ACB and ampe meter, volt meter, protection equipment as is Surge Arrestor, over-under voltage relay (O/UV) over current earth fault relay (OC/EF)
Communication capabilities + Supports all common communication options: transparency of switching states
and energy flows+ Early fault detection thanks to connection to higher-level control systems
+ Supports all common communication options: transparency of switching states and energy flows

+ Early fault detection thanks to connection to higher-level control systems

 

 

Simple integration of low-voltage power distribution components

MOUNTING DESIGN CIRCUIT BREAKER DESIGN CIRCUIT BREAKER DESIGN
Functions + Reliably protect people and plants

+ Precise and reliable recording of energy values for supply, electric feeders, and individual loads

+ Safe and rapid switch-off to protect against overloads and short circuits

Comprehensive protection of people and
plants against damage through fire, electric
shock, lightning, or overvoltage
Special features + Variable busbar positions at the top up to 6300 A

+ Optimal connection conditions in busbar connection compartment

 

+ The multi-profile bar allows for the simple
assembly of modular installation devices+ Boards for reactive power compensation with design verification according to IEC 61439 reduce transmission lossets+ Overview of power distribution, thanks to a standardized labeling system for sections and feeders

 

 

Simple integration of low-voltage power distribution components

MOUNTING DESIGN CIRCUIT BREAKER DESIGN CIRCUIT BREAKER DESIGN
Functions + A variety of connection options via vertical section busbars: flexible layout and optional expansions

+ Supply unit and feeder

+ Via cable or busbar trunking system from to 6300A

+ The functional compartments can be divided as required with add-on modules

+ Safe housing

+ Design verification by verification test
in accordance with IEC 61439-1&2

+ Frame made from stable sheet-steel profiles